Service manual

Conveyor Minimum Basic Requirements
1) Table with less then two racks “out” is not recommended.
2) A 90° curved table on the exit side is not recommended unless it is over ve racks distance (100”) from
the machine.
3) The minimum distance a sink or drain device can be to the entrance side (soil) of the conveyor is 20”.
And no such device should be on the clean side.
4) Less then ve racks out should have a limit switch installed on the exit table.
5) Incoming rinse water shall be rated 120F at 120 GPH. Or 180F at 120 GPH.
6) Electrical wire supply shall be 6 gauge, 3 ph, 208v at 60 amp clean circuit.
Single phase 208v, one 60 amp/6AWG service and one 50 amp/8AWG service with a Neutral
(10 AWG) and suitable ground. ADC-66 is 3 gauge, 3 ph, 208v at 90 amps.
7) Tables to be bolted to the machine on clean and soil sides as noted in installation sheet and manual.
8) Do not install chemical dispenser on top of control box or run chemical tubing over critical areas of the
machine top: plumbing, electrical boxes.
9) Do not install with 180° turn in the drain pipe. Make short runs and eliminate tight 90° elbows when
possible.
10) Adjust the tables to meet the machine. Do not adjust the tray track to meet an ill-formed table, x the
table. Tables must be slanted toward the machine; 0.5” drop over 70” of travel as a min.