Service manual
DISPENSERS
1. The fi nal rinse manifold has two ports (1/8” IPS, female) provided in the mixing chamber chemical
check-valves. The dispenser’s electrical connection points are provided in the control box. There are two
signals. For the 44 3-phase, a 208/240v signal labeled RINSE and a 208/240v signal labeled
DETERGENT. They are located in the lower left hand area of the control box, as you face the machine.
The 110v CONTROL (1amp) circuit produced by the transformer does not have the capacity to run a
dispenser. It is highly recommended that no device be attached to the control circuit of the machine, such
as dispensers and hood fans. Use the factory provided dispenser terminals in the control box. For the
66 3-phase, a 110v signal is provided and labeled for dispenser control in the lower left hand corner of the
control box, as you face it. This 110v power is available because of the neutral line and L1 of the incoming
power.
2. The wash tank has a 7/8” hole provided for a chemical probe. It is located at the front of the tank
adjacent to the pump fi lter and pump discharge manifold. There is also a 7/8” hole for the detergent inlet
located in the wash section above the scrap trays on the side of the well between the wash and rinse tanks.
This can be accessed behind the heater power box located in front of the rinse tank pump.
3. Do not mount the dispenser on top of the control box.
4. Secure all chemical lines and attachment points. Make sure that chemical lines do not run over the top
of electrical devices or inlet plumbing. (A leaking sanitizer line can destroy the stainless cabinet and
machine components).
7