Specifications
AT command set for XX Siemens mobile phones and modems   
_________________________________________________________________________________________ 
_________________________________________________________________________________________ 
Document No.:  A30880-A10-A001-XX-
D376 
Revision: Master R75     
Revision Date:  29. September, 2004     
  112 
AT^SPLM 
AT^SPLM  Read the PLMN list 
Test command  Response:  
AT^SPLM=? 
OK/ERROR/+CME ERROR 
Execute command:   Response: 
AT^SPLM 
^SPLM: numeric <oper
>,long alphanumeric <oper>[<CR><LF> 
^SPLM: numeric <oper
>,long alphanumeric <oper>[…]] 
OK/ERROR/+CME ERROR 
Parameter 
<oper
> 
Network operator in numeric and alphanumeric notation 
AT^SPLR
AT^SPLR  Read an entry from the preferred-operator list 
Test command  Response 
AT^SPLR=? 
^SPLR: (list of supported <index
>s) 
OK/ERROR/+CME ERROR 
Parameter 
<index
> 
Location numbers 
Write command   
AT^SPLR=<index1>[, <index2>] 
Response:  
^SPLR: <index
1>, numeric <oper> 
^SPLR: ..... 
^SPLR: <index
2>, numeric <oper> 
OK/ERROR/+CME ERROR 
Parameter 
<index
1> 
Location number where the read of the entry starts 
<index
2> 
Location number where the read of the entry ends 
<oper
> 
Network operator in numeric form 
AT^SPLW
AT^SPLW  Write an entry to the preferred-operator list 
Test command  Response 
AT^SPLW=? 
^SPLW: (list of supported <index
>s) 
OK/ERROR/+CME ERROR 
Parameter:  
<index
> 
Location number at which the entry is written 
Write command 
AT^SPLW=<index>[, <oper>] 
Response:  
OK/ERROR/+CME ERROR
Parameter: 
<index
> 
See Test command 
<oper
> 
Network operator in numeric form 
AT^SPST
AT^SPST  Play Signal Tone 
Test command  Response:  










