Specifications
AT command set for XX Siemens mobile phones and modems   
_________________________________________________________________________________________ 
_________________________________________________________________________________________ 
Document No.:  A30880-A10-A001-XX-
D376 
Revision: Master R75     
Revision Date:  29. September, 2004     
  30 
2 
CLIR suppression (not incognito) 
Read command  Response:  
AT+CLIR? +CLIR: <n>, <m> 
OK/ERROR/+CME ERROR 
Parameter:  
<n
> 
See Test command 
<m
> 
0  CLIR not provisioned (not incognito) 
    1  CLIR provisioned in permanent mode (incognito) 
 2 Unknown 
    3  CLIR mode presentation temporarily restricted (next call 
incognito) 
    4  CLIR mode presentation temporarily allowed (next call not 
incognito) 
Write command   
AT+CLIR=[<n>] 
Response 
OK/ERROR/+CME ERROR 
 Parameter:  
<n> 
 See Read command 
AT+CNUM
AT+CNUM  Read own numbers 
Test command  Response:  
AT+CNUM=? 
OK/ERROR/+CME ERROR 
Execute command  Response:  
AT+CNUM 
+CNUM: [<alpha
1>],<number1>,<type1>[<CR><LF> 
+CNUM: [<alpha
2>],<number2>,<type2> [...]] 
OK/ERROR/+CME ERROR 
Parameter:  
<alpha
x> 
optional alphanumeric string associated with <number
x>; used 
character set should be the one selected with AT+CSCS 
command. 
<number
x> 
string type phone number of format specified by <typex> 
<type
x> 
type of address octet in integer format (see GSM 04.08 [8] 
subclause 10.5.4.7) 
AT+COLP
AT+COLP  Connected Line Identification Presentation 
Test command  Response: 
AT+COLP=? 
+COLP: (list of supported <n
>s) 
OK/ERROR/+CME ERROR 
Parameter:  
<n
> 
0 
Disable 
1 
Enable 
Read command  Response:  
AT+COLP? +COLP: <n>, <m> 
OK/ERROR/+CME ERROR 
Parameter:  
<n
> 
  See Test command 
<m
> 
0 
COLP not provisioned (no presentation) 
1 