Specifications
AT command set for XX Siemens mobile phones and modems   
_________________________________________________________________________________________ 
_________________________________________________________________________________________ 
Document No.:  A30880-A10-A001-XX-
D376 
Revision: Master R75     
Revision Date:  29. September, 2004     
  42 
AT+CPBR
AT+CPBR  Read a telephone-book entry 
Test command  Response:  
AT+CPBR=? 
+CPBR: (list of supported <index
>s), <nlength>, <tlength> 
OK/ERROR/+CME ERROR 
Parameter: 
<index
> 
Location number 
<nlength
> 
Max. length of telephone number 
<tlength
> 
Max. length of text corresponding to the number 
Write command 
AT+CPBR=<index1>[,<index2>] 
Response: 
[+CPBR: <index1>, <number>, <type>, <text >[[…]<CR><LF> 
+CPBR: <index
2>, <number>, <type>, <text>]] 
OK/ERROR/+CME ERROR 
Parameter:  
<index1
> 
Location number where the read of the entry starts 
<index2
> 
Location number where the read of the entry ends 
<number
> 
Telephone number 
<type
> 
Type of number 
<text
> 
Text corresponding to the telephone number 
<text
> depends on AT+CSCS. 
Note: 
In the <text
> field, special characters like the following may 
be displayed:  
`"` (0x22), `@` (0x00), `ò` (0x08), `Ö` (0x5c). 
See also section AT+CPBW and  
Appendix A: “How to use special characters in certain 
commands ( e. g., AT+CPBW”). 
Empty entries do not produce any output. 
AT+CPBS
AT+CPBS  Select a telephone book 
Test command  Response:  
AT+CPBS=?  +CPBS: (list of supported <sto>s) 
OK/ERROR/+CME ERROR 
Parameter: 
<sto
> 
FD 
SIM fix-dialing phonebook 
SM 
SIM phonebook 
DC 
ME Dialled Calls List 
ON 
SIM (or ME) own numbers (MSISDNs) list 
LD 
SIM last-dialling phonebook 
MC 
ME missed (unanswered received) calls list 
RC 
ME received calls list 
  For a description of telephone-book features, see section 3.1.2. 
Read command  Response: 
AT+CPBS? 
+CPBS: <sto
>,<used>,<total> 
OK/ERROR/+CME ERROR 
Parameter:  