AT+CGQMIN? +CGQMIN: 
<cid
>,<precedence>,<delay>,<reliability>,<peak>,<mean>[ 
<CR><LF>+CGQMIN: 
<cid
>,<precedence>,<delay>,<reliability>,<peak>,<mean>[…]] 
OK/ERROR/+CME ERROR 
Parameter: 
<cid
> 
numeric PDP Context Identifier 
<PDP_type
> 
See Test command 
<precedence
> 
See Test command 
<delay
> 
See Test command 
<reliability
>
See Test command 
<peak
> 
See Test command 
<mean
> 
See Test command 
Write command 
AT+CGQMIN=[<cid>[,<precedence>[,<delay>[,<reliability>[,<peak>[,<mean>]]]]]] 
Response:  
OK/ERROR/+CME ERROR 
Parameter:  
<cid
> 
See Read command 
<PDP_type
> 
See Test command 
<precedence
> 
See Test command 
<delay
> 
See Test command 
<reliability
>
See Test command 
<peak
> 
See Test command 
<mean
> 
See Test command 
AT+CGQREQ
AT+CGQREQ  Quality of Service Profile (Requested) 
Test command  Response: 
AT+CGQREQ=? 
+CGQREQ: <PDP_type
>, (list of supported <precedence>s), (list of 
supported <delay
>s), (list of supported <reliability>s) , (list of 
supported <peak
>s), (list of supported <mean>s)[<CR><LF> 
+CGQREQ: <PDP_type
>, <precedence>, <delay>, <reliability>, 
<peak
>, <mean>[…]] 
OK/ERROR/+CME ERROR 
Parameter:  
<PDP_type
> 
string parameter of Packet Data Protocol type 
PPP 
Type PPP 
IP 
Type IP 
<precedence
> 
numeric parameter for the precedence class 
0 
network subscribed value 
1..3 
<delay
> 
numeric parameter for the delay class 
0 
network subscribed value 
1..4 
<reliability
>
numeric parameter for the reliability class 
0 
network subscribed value 
1..5 
<peak
> 
numeric parameter for the peak throughput class 
0 
network subscribed value 
1..7 