Specifications
   AT command set for XX Siemens mobile phones and modems 
__________________________________________________________________________________________ 
 Document No.: A30880-A10-A001-XX-
D376 
 Revision: Master R75 
    Revision Date:  29. September.2004 
 63 
Write command 
AT+CGQREQ=[<cid>[,<precedence>[,<delay>[,<reliability>[,<peak>[,<mean>]]]]]] 
Response: 
OK/ERROR/+CME ERROR 
Parameter:  
<cid
> 
See Read command 
<precedence
> 
See Test command 
<delay
> 
See Test command 
<reliability
> 
See Test command 
<peak
> 
See Test command 
<mean
> 
See Test command 
AT+CGPADDR
AT+CGPADDR  Show PDP address 
Test command  Response: 
AT+CGPADDR=? 
+CGPADDR: (list of defined <cid
>s) 
OK/ERROR/+CME ERROR 
Parameter: 
<cid
> 
numeric PDP Context Identifier 
Write command 
AT+CGPADDR=[<cid> ,[< cid> [,<cid> [,…]]]] 
Response:  
+CGPADDR: <cid
>,<PDP addr>[<CR><LF> 
+CGPADDR: <cid
>,<PDP addr>[...]] 
OK/ERROR/+CME ERROR 
Parameter: 
<cid
> 
See Test command 
<PDP addr
> 
IP address of PDP 
AT+CGREG
AT+CGREG  GPRS network registration status 
Test command  Response: 
AT+CGREG=? 
+CGREG: (list of supported <n
>s) 
OK/ERROR/+CME ERROR 
Parameter: 
<n
>  0 
Suppresses the unexpected network status messages 
1 
Enable the unexpected network status messages 
Unsolicited result code 
OK/ERROR/+CME ERROR 
Read command  Response: 
AT+CGREG? 
+CGREG: <n
>,<stat> 
OK/ERROR/+CME ERROR 
Parameter: 
<n
> 
See Test command 
<stat
> 
Status 
0 
Not registered, not currently searching 
1 
Registered home network 
2 
Not registered, but currently searching 
3 
registration denied by network 
4 
Unknown 
5 
Registered, roaming 