Specifications
   AT command set for XX Siemens mobile phones and modems 
__________________________________________________________________________________________ 
 Document No.: A30880-A10-A001-XX-
D376 
 Revision: Master R75 
    Revision Date:  29. September.2004 
 77 
AT+CBST =? 
+CBST: (list of supported <speed
>s), (list of supported <name>s), (list of 
supported <ce
>s) 
OK 
Parameter: 
<speed
>   
0 
auto bauding 
4 
2400 bps ( V.22bis) 
6 
4800 bps ( V.32) 
7
9600 bps (V.32) 
14 
14400 bps (V.34) 
68 
2400 bps (V.110) 
70 
4800 bps (V.110) 
71 
9600 bps (V.110) 
75 
14400 bps (V.110) 
<name
> 0 
asynchronous modem 
<ce
> 1 
non-transparent 
Read command  Response: 
AT+CBST? 
+CBST: <speed
>,<name>,<ce> 
OK/ERROR/+CME ERROR 
Write command 
AT+CBST=<speed>[,0,1] 
Response:  
OK/ERROR/+CME ERROR 
Parameter: 
<speed
> 
See Test command 
AT+CRLP
AT+CRLP  Select radio link protocol parameter for originating non-transparent data call 
This modem command sets radio link protocol (RLP) parameters used when non-transparent data 
calls are initiated. This command returns supported values as a compound value. 
Test command  Response: 
AT+CRLP=? 
+CRLP: (list of supported <iws
>s), (list of supported <mws>s), (list of 
supported <T1
>s), (list of supported <N2>s) 
Parameter: 
<iws
> 
Interworking window size (IWF to MS) 
0-61
Default: 61 
<mws
> 
Mobile window size (MS to IWF) 
0-61
Default: 61 
<T1
> 
Acknowledgement timer (T1 in 10 ms units)  
 48-255 
Default: 78 
<N2
> 
Re-transmission attempts N2 
 1-255 
Default: 6 
Read command  Response 
AT+CRLP?  The command returns current settings for the supported RLP version 0. 
+CRLP: <iws
>,<mws>,<T1>,<N2> 
OK 
Parameter:  