Specifications
   AT command set for XX Siemens mobile phones and modems 
__________________________________________________________________________________________ 
 Document No.: A30880-A10-A001-XX-
D376 
 Revision: Master R75 
    Revision Date:  29. September.2004 
 93 
AT+GCAP 
AT+GCAP  Request Capabilities List 
Test command  Response:  
AT+GCAP=? OK/ERROR 
Read command  Response:  
AT+GCAP? 
+GCAP: <mode
> 
Parameter 
<mode
> : e.g. “+GCAP: AT+CGSMS , AT+FCLASS” 
AT+IPR
AT+IPR  Fixed DTE rate  
Test command  Response: 
AT+IPR=? 
+IPR: (list of supported <rate
> values) 
OK/ERROR/+CME ERROR 
Parameter: 
<rate
> 
bits per second at which the DTE-DCE interface is to operate. The set 
of supported values can be retrieved by means of the Test command. 
0 
Auto-bauding 
Read command  Response: 
AT+IPR? 
+IPR: <rate
> 
OK/ERROR/+CME ERROR 
  Parameter: 
<rate
> 
See Test command 
Write command:  Response: 
AT+IPR=<rate> +IPR: <rate> 
OK/ERROR/+CME ERROR 
 Parameter: 
<rate> 
See Test command 
2.9  Siemens defined commands 
Since user-defined commands cannot be implemented according to official syntax, the character string ”+C” is 
replaced by ”^S” (”^” = 0x5E). In future, if a user-defined command is accepted in the syntax prescribed in 
3GPP TS recommendations, the command can be addressed using either command string. 
AT^SABD
AT^SABD  Accessory for Bluetooth Data 
Test command 
Response
 : 
AT^SABD=? 
^SABD: (list of supported <mode
>s) 
OK 
Parameter: 
<mode
> 
See Write command 
Read command  Response: 
AT^SABD? 
^SABD: <mode
> 
OK 
Write command 
AT^SABD=<mode>[,<data>] 
 Response: 
[^SABD: <data>] 
OK
Parameter: 