User's Guide

Recommended mounting height
135cm
120 cm
Default Mounting bracket (optional)
2.1.2. Electrical Requirements
Use a stable power supply adapter of DC 15V (± 5%) with a minimum 3.5A.
Make sure that the power cable is as short as possible and have correct wire gauge (min. 22
AWG)
Use CAT5 or later for ethernet cable.
Table 2. Power requirements depending on cable length and wire gauge
Input voltage (V) Wire gauge (AWG)
Power cable length (m)
Recommended Maximum
15
20 30.0 37.5
22 18.9 23.6
18
20 48.0 60.1
22 30.2 37.7
NovaFace User Guide, 0.1
May 2020
Page
10 of 28
www.cmi-tech.com
(c) 2020, all rights reserved