Install guide

Supported Bosch
MPEG-4/H.264 IP cam-
eras
AutoDome Junior HD / HD IVA
AutoDome 100/200/300/500
AutoDome Easy IP / IP II / IP II E
Axis MPEG4 (no PTZ)
Dinion IP (MPEG4)
NBN-823V-P
Dinion NBN-832V-P HD
Dinion NBN-921-P
Dinion NBx 4xx P / P IVA
Dinion NBx 4xx P SD / P SD IVA
Dinion NDx 4xx P SD / P SD IVA
Extreme IP
FlexiDome IP
FlexiDome NDN-921-P
FlexiDome NDx 4xx P / P IVA
NBC 255-P / 265 P / 225 P
NDC 265 P / 225-P / 225 P I
NDC-255-P / 255 P I
VG4 AutoDome (H.264 IP module)
VG5 AutoDome HD / SD
VOT 320V
Supported Bosch H.264
and MPEG-4 encoders
(video servers)
VideoJet 10/1000
VideoJet X10 / X20 /X40
VideoJet X10 SN / X20 SN / X40 SN
VIP X1 XF / X1 XF E
VIP10
VIP 1600 / 1600 XFM4
VIPX1 / VIPX1A / VIPX2 / VIPX2A
VJ8004 / VJ8004A
VJ8008 / VJ8008A
Supported Bosch JPEG
IP cameras
NWC-0700/0800 Megapixel IP camera
NWC-0900 Day/Night Megapixel IP cam-
era
Supported JPEG IP cam-
eras from other manufac-
turers
IP cameras from Arecont Vision, Axis, Mo-
botix, Sony and other compatible cameras
that support HTTP/TFTP and provide fixed
path to JPEG image
Maximum recording rate 100 Mbit per second
Maximum number of con-
nected cameras:
64
Maximum number of con-
figured remote station at
one receiver station
200 (can be configured, visible in devices
list)
Number of simultaneous-
ly connected remote sta-
tions at one receiver sta-
tion
Maximum: 32
Supported Languages German, English, French, Portuguese,
Spanish, Swedish
HTTP Browser Access
(WAN)
Installed. A custom HTTP port is possible.
BRS WebServer ActiveX required on browser
Operating system BRS
Appliance
Windows 7 (32-bit)
Device Compatibility / Integration features
Bosch Video Management
System
Version 2.3.1 and 3.0
Requires 1 Gbit/s connections to central
server and workstation; communication
via TCP Port 135 plus 4 TCP ports and
4 UDP ports dynamically assigned in the
range from 1025 to 65535
ATM integration
DTP3N via RS232 (only EMEA)
ATM/POS integration Bosch ATM/POS bridge via TCP/IP
IP server integration
Any IP server using socket connections
for communication
Alarm panel integration
(intrusion, fire, access)
Integration via RS232:
AZ1010, BZ500, BZ1012, BZ1060,
FPA5000, G-Series Panels, NZ500,
NZ1008, NZ1012, NZ1060, UEZ,
UGM2020
Digital I/O modules (max.
8 per BRS)
Digital I/O Advantech ADAM-6017,
ADAM-6018, ADAM-6022, ADAM-6024,
ADAM-6050, ADAM-6050-W,
ADAM-6051, ADAM-6051-W,
ADAM-6052, ADAM-6055, ADAM-6060,
ADAM-6060-W, ADAM-6066
Virtual inputs
External software can trigger events via
virtual inputs over TCP/IP
Uninterruptible Power
Supply (UPS)
Loss of power can cause corrup-
tion of the Operating System or
the stored video. To avoid loss of
data and ensure trouble-free oper-
ation, we recommend installing an
UPS for critical applications.
To connect and configure the UPS,
observe the manufacturer's docu-
mentation delivered with the UPS.
The UPS is not contained in the
product.
Electromagnetic Compatibility (EMC)
USA
FCC Part 15, Class A
EU
EMC Directive 204/108/EC
Interference immunity: Conform-
ance with EN 50130-4
For Tower: To comply with
EN50130-4 voltage interruption
an external UPS is required. The
UPS is not contained in the prod-
uct. The UPS should be dimen-
sioned for at least 960 VA.
Interference emission: EN 55022,
Class A
Mains power fluctuations: EN
61000-3-2
Voltage fluctuations: EN
61000-3-3
Safety
USA UL 60950-1, 2nd edition
CAN/CSA-C22.2 No.60950-1-07, 2nd
edition
EU EN 60950-1:2006 + A11:2009
4 | Bosch Recording Station Appliance
EXHIBIT B
5/7/2013 - LBUSD - BOSCH SECURITY CAMERA SYSTEMS
125 of 183