Instruction Manual
Table Of Contents
- Reversion of History
- Part 1. Installation Manual
- Part 2. User’s Manual

28
BDx-Series Installation & User’s Manual
2.2.3 Connecting Sensor Input
<DIO Board>
Connect one signal line of sensor (infrared rays sensor, heat perception sensor, magnetic sensor) to the desired
sensor number and then connect another line to the ‘COMMON’ port. (You can set the type-NC or NO- of sensor
at “Setup” mode -> “DIO”).
Use another Adapter for the all sort of sensor’s power supply.
2.2.4 Connecting Digital Output
<DIO Board>
Use this at 12V or less operating voltage and 300mA or less operating current.
When controlling lamp and AC operated equipment, control it using separate outside relay.
During normal operation the control output contact is maintained at “Open” status, and during control output
the output contact is changed to “Close(short)” status.