Specifications

XPEED Indoor Series WWW.CNBTEC.COM
2. Installation
9 Before installing the camera, you should set the DIP switches to configure the camera ID, communication protocol. Do not use the
system upgrade terminal.
~ DIP Switch Setup
Camera ID Setup
ID number of camera is set using binary number.
The example is shown bellow.
Pin 1 2 3 4 5 6 7 8
ID Value 1 2 4 8 16 32 64 128
ex) ID=5 ON OFF ON OFF OFF OFF OFF OFF
Ex) ID=10 OFF ON OFF ON OFF OFF OFF OFF
The range of ID 1~255. Do not use 0 as camera ID.
Factory default of Camera ID is 1.
If you want to control a certain camera, you must match the camera ID with Cam ID setting of
DVR or Controller.
Communication Protocol Setup
Select the appropriate Protocol With DIP switch combination.
Switch state
Protocol/Baud rate
P0 (Pin 1) P1(Pin 2) P2(Pin 3)
OFF OFF OFF PELCO-D, 2400bps
ON OFF OFF PELCO-D, 9600bps
OFF ON OFF PELCO-P, 4800bps
ON ON OFF PELCO-P, 9600bps
OFF OFF ON SAMSUNG, 4800bps
ON OFF ON PANASONIC, 9600bps
Others Reserved