MSDS
新 利 達 電 池 有 限 公 司
NEW LEADER BATTERY LIMITED.
Material Safety Data Sheet for Alkaline Battery (LR6,LR3) Series
Document Number: MSDS-Alkaline Battery (LR6,LR3) Series (Version : 2012)
Prepared 02 January 2012
SECTION IV – Fire and Explosion Hazard Data
Flash Point (Method Used) : N.A.
Flammable Limits : N.A.
LEL : N.A.
UEL : N.A.
Extinguishing Media : Carbon Dioxide, Dry Chemical or Foam Extinguishers.
Special Fire Fighting Procedures : N.A.
Unusual Fire and Explosion Hazards
Do not dispose the battery in fire – May Explode
Do not short-circuit the battery – May cause burns
Emergency Responders should wear self-contained breathing apparatus.
If the battery fire, it is permissible to use any class of extinguishing medium on these batteries or their packing
material. Cooled the case of batteries if exposed to fire to prevent rupture
SECTION V – Reactivity Data
Stability:
Unstable Conditions to Avoid
Incompatibility : Materials to Avoid
Hazardous Decomposition or Byproducts
When heated, battery may emit hazardous vapour of KOH/NaOH
The Alkaline Button Battery do not meet any of the criteria established in 40CFR 261.2 of reavtivity
SECTION VI – Health Hazard Data
Route(s) of Entry
Inhalation : N.A.
Skin : N.A.
Ingestion : N.A.
Health Hazard (Acute and Chronic) / Toxicological information
In case of electrolyte leakage , skin will be itchy when contaminated with electrolyte
In contact with electrolyte can cause severe irritation and chemical burns
Inhalation of electrolyte vapors may cause irritation of the upper respiratory tract and lungs
Page 2 of 4