FAX NO. (904) 641-1697 Coastal Industries Inc. P.O BOX 16091 JACKSONVILLE, FLORIDA 32246 *** TELEPHONE NO.
Paragon Bi - Fold Door ( right strike configuration shown) Exploded View - Outside of Unit Looking In PARAGON_BI-FOLD_08/27/2015 * * * PATENTS PENDING (2)
PARTS K EY PART LE TTE R NUMBER DESCRIPTION A 900 SILL 1 B 941 GUIDE TRACK, SILL / HEADER 2 C 903 WALL JAMB 2 D 926 STRIKE POST 1 e1 920 Hinge Post 1 e2 922 Hinge Stile 3 e3 924 Strike stile 1 e4 925 Rail 4 e5 940 Center Hinge Pull 1 e6 37 Slide Piece 2 e7 C P 932 Hinge Pins (not shown) 6 e8 CP148TW Hinge Washer (not shown) 6 e9 C 921B Hinge Sleeve (not shown) 3 e10 C 940B Glazing Vinyl (not shown) --- e11 98-42 Magnetic Strip (not shown) 1 e
5. Before proceeding, determine which side you want your door to strike (left or right, your choice). Now measure the opening width between the two Wall Jambs (C) as shown in figure 3 and trim strike side end of Sill Guide Track (B) to measurement obtained (always trim the strike side end, never the hinge side end). With Guide Track’s high lip toward exterior, snap Track (B) into place as shown. See also exploded view - sheet 2. figure 3 6. Strike side was determined in step 5 . . .
12. Step inside the shower enclosure and close the Door. Check to make sure that bottom of Door Assembly (E) is parallel to the Sill (A). If it is not, make it so. When satisfied that the Door Assembly is parallel to the Sill, secure Hinge Post (e1) and Strike Post (D) to the Wall Jambs using six(6) 638PHPT Installation Screws (O) see exploded view - sheet 2. 13. Attach and center the Strike Plate face to the Magnet Holder Assembly and shown in figure 8a.