User manual
C-Com Satellite Systems Inc Page 38 of 77
iNetVu™ 5000 Controller User Manual
Revision 1.0.2
Angle and Limit Switch Indicators
Displays real-time angles and Limit Switch status
Fig. 24: Angle and Limit Switch Indicators
• When the Elevation STOW Limit Indicator is ON, the Elevation Angle will change
to “–90”, to denote that the iNetVu™ Mobile Platform is now stowed. It will remain
“-90” until the indicator turns OFF.
• For iNetVu™ 1200 Mobile Platforms, the Polarization Stow Indicator will
ALWAYS be ON.
• A YELLOW-colored “F” will appear if a Limit Switch has been disabled in the
Advanced Maintenance Menu
• If the Polarization is disabled (for circular signal frequency bands such as Ka-
Band or X-Band), the Polarization Angle will display 0.00 and the Polarization
Stow Switch must be closed.
Elevation UP Limit Indicator
Elevation DOWN Limit Indicator
Elevation STOW Limit Indicator
A
zimuth STOW Limit Indicato
r
Polarization STOW Limit Indicator
Elevation Angle
Azimuth Angle
Polarization Angle