User manual

C-Com Satellite Systems Inc Page 66 of 77
iNetVu™ 5000 Controller User Manual
Revision 1.0.2
The Inclinometer is installed with an offset in order to produce an accurate Elevation
Angle reading. Each type of Mobile Platform has its own default offset value.
This value is normally changed when performing the Target Calibration process to
compensate for un-level surroundings, and should be left at this updated value.
PLATFORM TYPES
MF1200 ME1200 A1200C A1200B A0980B MF950 ME950 A0950B
EL OFFSET 42.00 42.00 42.00 42.00 31.00 25.00 31.00 31.00
PLATFORM TYPES
MF740 ME740 A0740B A1800A A0660A
EL OFFSET 25.40 31.00 31.00 46.5 55.00
Fig. 54: Default Elevation Offsets. All values are + 2
°
after Target Calibration.
Azimuth Parameters
Fig. 55: Advanced Maintenance – Azimuth Parameters
The Azimuth Angle is based on 2 values:
AZ Pot Factor
AZ Pot Zero
AZ Pot Factor is an A/D value from the potentiometer which allows the iNetVu™ Mobile
Software to convert the A/D value of the Potentiometer into an equivalent angle. The AZ
Pot Factor should vary approximately +
15% from the Default values below.
AZ Pot Zero is an A/D value from the potentiometer which physically determines where
the iNetVu™ Mobile Software places Azimuth Angle 0°. The AZ Pot Zero may vary
approximately +
15% from the Default values below.
The AZ Pot Factor and AZ Pot Zero are calculated during the Azimuth Calibration
process.
PLATFORM TYPES
MF1200 ME1200
A1200B
A1200C
A0980B MF950 ME950 A0950B
AZ POT ZERO 376.14 286.1878 286.1878 343.0747 226.0722 343.0747 343.0747
AZ POT FACTOR 0.737 0.5525 0.5525 0.6683 0.4515 0.6683 0.6683