User manual
C-Com Satellite Systems Inc Page 67 of 77
iNetVu™ 5000 Controller User Manual
Revision 1.0.2
PLATFORM TYPES
MF740 ME740 A0740B A1800A A0660A
AZ POT ZERO 226.0722 343.0747 343.0747 280.7808 343.0747
AZ POT FACTOR 0.4515 0.6683 0.6683 0.5484 0.6683
Fig. 56: Azimuth Potentiometer Default Values
Polarization Parameters
The Polarization Angle is based on 2 values:
• PL Pot Factor
• PL Pot Zero
PL Pot Factor is an A/D value from the potentiometer which allows the iNetVu™ Mobile
Software to convert the A/D value of the Potentiometer into an equivalent angle. The PL
Pot Factor should vary approximately +
15% from the Default values below.
PL Pot Zero is an A/D value from the potentiometer which physically determines where
the iNetVu™ Mobile Software places Polarization Angle 0°. The PL Pot Zero may vary
approximately +
15% from the Default values below.
The PL Pot Factor and PL Pot Zero are calculated during the Polarization Calibration
process.
PLATFORM TYPES
MF1200 ME1200
A1200B/
A1200C
A0980B MF950 ME950 A0950B
PL POT ZERO 250.2905 203.066 203.066 128.5094 80.2096 128.5094 128.5094
PL POT FACTOR 0.5304 0.3852 0.3852 0.2574 0.1586 0.2574 0.2574
PLATFORM TYPES
MF740 ME740 A0740B A1800A A0660A
PL POT ZERO 80.2096 128.5094 128.5094 205.4144 128.5094
PL POT FACTOR 0.1586 0.2574 0.2574 0.4012 0.2574
Fig. 57: Polarization Potentiometer Default Values
Disable Rotation
An option that is used for circular-signaled frequency bands such as X-Band or Ka-Band.
It will only be available for the A0660A and A1800A Mobile Platforms. By default, the
Polarization will be disabled for the A0660A Mobile Platform, and enabled for the
A1800A Mobile Platform. This function can only be accessed via CONFIG Mode, and
the Polarization ST Limit Switch must be closed and permanently display ST.