When checked, the Polarization Angle will display 0.00.
Demo / Test
Opens System Test and Demo menu screen
Send < Parameter Name >
Sends associated parameters to the iNetVu™ Controller’s EPROM
memory. The system will prompt the user and ask whether to save these
parameters to the EPROM. The values saved only in memory and not
EPROM will be lost when the controller is reset.
Write EPROM
Sends and writes ALL
the parameter’s to the iNetVu™ Controller’s
EPROM.
Send All
Sends ALL
parameters to the controller’s memory. The system will
prompt the user and ask whether to save these parameters to the
EPROM.
Read All
Reads ALL
parameters from the iNetVu™ Controller’s EPROM memory
and sets the values into the iNetVu™ Mobile Software
Save Registry
Sends ALL
parameters to the local registry
Read Registry
Reads ALL
parameters from the local registry and sets the values into the
iNetVu™ Mobile Software
Advanced
Opens Advanced Maintenance menu
Calibrate PL
Performs automated Polarization Calibration process.
i. Antenna will completely rotate counter-clockwise to the physical
limit and temporarily record the A/D value from the Potentiometer.
ii. Antenna will completely rotate clockwise to the physical limit and
temporarily record the A/D value from the Potentiometer.
iii. Based on the A/D values of the two (2) physical limits, and the
maximum range of motion for the Mobile Platform, the PL Pot
Factor is calculated.
iv. Antenna will center itself and attempt to locate the cut-off edges of
the Polarization Stow Switch.
v. After detecting at which angles the ST Switch turns OFF, the
Polarization zero position is calculated and the PL Pot Zero is set