Remote Control connector
The 25 way D type connector on the rear panel allows remote control of the generator.
Below is a description of the various remote functions.
Pin Function
1 Remote power neg. 14 RF Off light
2 Remote power pos. 15 Enable Remote ON
3 Incident power 16 Enable Aux Feedback
4 Reflected power 17 Enable Remote power
5 Remote RF On 18 -
6 - 19 RF On light
7 Ground 20 -
8 Ground 21 Enable True Power mode
9 Auxiliary feedback neg. 22 -
10 Auxiliary feedback pos. 23 -
11 - 24 -
12 - 25 +12V out for interlock
13 External interlock