Description Of 3 Phase Mains Input Connection
Round connector pinout
Pin 1 Reserved
Pin 2 Reserved
Pin 3 Live Phase 2
Pin 4 Earth
Pin 5 Live Phase 3
Pin 6 Live Phase 1
Pin 7 Neutral
Neutral is mandatory, failure to provide
a neutral will result in damage
Pulse Operation.
Pulse mode is selected by the Pulse / CW switch on the front panel. The pulse signal
should be TTL (active high). Minimum pulse width is 40s and with duty cycle from 1%
to CW (duty cycle below 1% will cause power level to deviate from set value). The front
panel displays (and remote outputs) store the last value of output power from the pulse,
maintaining the reading for the duration of the off time.