Operating instructions
CPS:Doc 20017 V1 24/01/2012  Page 3  Issue 1 24/01/2012 
An external voltage of 0 to 5Volts can be used to control the output. This is particularly 
useful  in  sputter  coating  applications  where  the  d.c.  voltage  developed  across  the 
plasma dark space can be controlled rather than the RF power. 
General Specifications – RFG4K-13 and RFG4K-27 RF Generators 
Output frequency 
RFG4K-13, 13.56MHz. 
RFG4K-27, 27.12MHz. 
Output power 
4000Watts 
Frequency stability 
Crystal controlled: 
13.56MHz +/-1.4kHz 
27.12MHz +/-2.7kHz 
Output impedance 
50 
Output connection 
7/16 type/50  
Power control 
Analogue control system 
allows power or external 
feedback control. Output 
stability is +/-1% for +/-15% 
variation in line. 
VSWR capability 
Can withstand any VSWR at 
any phase angle 
Harmonic output 
Better than 40dB below 
fundamental 
Output envelope 
ripple 
Less than 1% of full 
amplitude 
Pulse operation 
SMA TTL input on rear 
panel. 
Minimum pulse width 40s. 
The external power control 
signal should vary the peak 
output from 0 to 4000W, 
with a pulse-on duty cycle 
from zero to continuous DC 
(100% duty cycle.) 
The front panel display 
automatically shows pulse 
output levels by utilising 
sample/hold technology 
Front panel controls 
Line 
RF on 
RF off 
Output power set 
Pulse/CW switch 
Remote switches 
Menu switches 
Front panel indicator 
RF power on 
RF power off 
Front panel display 
Vacuum fluorescent display 
showing: 
Forward (Incident) Power 
Reflected Power 
Reflected power exceed 
limit 
Remote operation 
Timer 
Cooling interlock 
External interlock 
AMN display (option) 
Rear panel 
switches/connectors 
Remote connector (25-way 
‘D’) 
Common exciter 
output(SMA) 
Common exciter 
input/external signal 
source(SMA)(max. 13dBm) 
Pulse input connector 
(SMA) 
Line input 
AMN display(option) 
RF output connector (N50) 
Remote control 
Accessed via rear panel 25-
way ‘D' type socket 
indicators: 
RF on/off (open collector 
100mA) 
Incident power 
Reflected power 
RF on/off (contact closure) 
Interlock (contact closure) 
Output set 0-5Volts = 0-
100% 
Remote output set request 
External feedback 
Remote RF on/off request 
Cooling 
Forced air – air intake 
through front, exhaust 
through rear 
Line 
380-415 VAC Three phase 
and Neutral 
50/60Hz 
Size 
Full rack mounting 5U high 
550mm deep (external 
connectors may protrude an 
extra 50mm) 
Weight 
25kg 
Finish 
Front Panel -RAL7135 light 
grey 
Rear Panel - Stainless Steel 
Cover - Stainless Steel 
Environment 
Operating temperature: 
0-35°C (-20° to +65° C 
storage) 
Standards 
EN61000-3-2:2006 
EN6100-3-3/A2:2005 
EN61326-1:2006 
EN61010-1:2001