Interlock Indicators:
Ref. Pwr: this is a warning of a high reflected power level and illuminates if the
reflected power exceeds 16% of the maximum capable generator output.
Cooling: this relates to over temperature of the internal power amplifier
module. If illuminated, RF On will not function until module has reached a safe
temperature.
NB. This interlock will operate when there is :
Inadequate ventilation
Defective cooling.
RF module fault.
In the event that RF operation is interrupted the interlock state will latch until
cleared by pressing RF off or removing the “Remote RF on” signal.
Ext. interlock: this is operated by connecting the 25 way d connector (remote) on
the rear panel pin 13 to +12V pin 25.
NB. when ext. Interlock (or any other interlock) is not made, the RF Off light will
not illuminate.
Remote: this operates when either remote output set or remote RF On/Off
request are enabled.