User`s manual
100-M0074X1    14 of 24 
www.cobham.com/gms 
to verify that a write operation has been correctly performed. An example scenario would be 
to 1) enable all fields, 2) change desired field(s), 3) perform a ‘Update’ (write) operation, 4) 
perform a ‘CLR’ operation and 5) perform a ‘Query’ operation. As a result of the ‘Query’ 
operation, the fields on the screen should all update to those values that were written during 
the ‘Update’ operation. 
•  “Store All Setup Pages” Button: Clicking on this button will store all setup pages, even if 
they are not shown. 
•  “Reset Tx” Button: Clicking on this button will reset/reboot the MDT-A unit. The system 
parameters will be restored to the last saved settings. Reset time is approximately 20 seconds. 
5.3.2  Field Definitions 
There are several different fields that can be configured by the MDT Configurator. The fields 
located in the main screen of Figure 5 and their associated values are defined in Table 3 below. 
Also noted in the table is whether the field is read, write-able or both 
Table 3 – MDT-A Field Definitions 
Field  R/W  Description 
Unit Name 
R/W 
Allows the user to assign a unique unit name to the 
MDT. 
Unit Number 
R/W 
Allows the user to assign a unique unit number to 
the MDT 
RF Freq 
(MHz) 
R/W 
RF output frequency. Desired frequency is entered 
in MHz (i.e., 1.296 GHz would be entered as 1296). 
Default frequency step size is 500 KHz. For S2 band 
it’s 250 KHz. 
Modulation 
Mode 
R/W 
Modulation mode. Desired modulation mode is 
selected from the following values: C-OFDM 
(default) Off (shuts off modulation) or I/Q CAL ON 
(puts unit in calibration mode). 
C-OFDM 
Bandwidth 
R/W 
COFDM transmit bandwidth. Desired bandwidth is 
selected from the following values: 6, 7 or 8 MHz. 
C-OFDM 
Mode 
R/W 
COFDM modulation type. Desired COFDM 
modulation type is selected from the following 
values: QPSK, 16QAM or 64 QAM (only in ASI 
mode) 
Mod Guard 
Interval 
R/W 
Modulation guard interval size. Desired modulation 
guard interval size is selected from the following 
values: 1/32, 1/16, 1/8 or ¼.  
Modulation 
FEC 
R/W 
Modulation FEC (Forward Error Correction) rate. 
Desired modulation FEC rate is selected from the 
following values: ½, 2/3, ¾, 5/6, 7/8 . 
Channel Rate 
(Mbps) 
R 
Channel rate is displayed based on parameters 
selected such as COFDM mode, FEC and Guard 
Interval. Channel rate must be set to be greater 
than the ASI stream rate. Set the channel rate to at 