3. Turn the selector knob to go to a setting, then press the selector knob to
change the setting.
4. Press EXIT to return to normal radio operation.
Radio setup
Parameter Description
Scan Hang
Time
Scan hang time, in seconds on an active receiving working
channel. The time is measured from the signal is detected. The
radio remains on the channel for the set time interval, if a signal
was detected.
OFF: Resumes scanning when signal disappears (default)
4, 6, 8, 10: Hang time in seconds.
Scan
Resume
Scan resume time, in seconds. When the programmed time of
inactivity has elapsed, and when watch/scan has been aborted
using a press on PTT, or after power-up, scan or watch is
resumed.
OFF: Automatic resume is deactivated (default)
3, 6, 10, 15, 20, 25, 30: Resume time in seconds.
Watch
Mode
DUAL: Dual watch monitoring the working channel and the
priority channel (channel 16, default for international channels).
TRIPLE: Triple watch. The working channel is watched with the
priority channel (channel 16) and the programmed call channel
(if any, otherwise dual watch).