Operation Manual

Electric motor performance P = 1500 W S3 (8 mi
n/2 min)
50 – 250 mm
520
Problem possible cause remedy
Logs are not bein
g split properly
(insufficient splitting performance)
The log is not positioned correctly
The log exceeds the maximum
dimensions or the wood is too hard for
the performance of the machine
The splitting wedge is not working
properly
Oil leak
Hydraulic pressure too low
Incorrect connecting lead (longer than
10 m or too small cable cross-section)
Reposition the log correctly
Cut the log to the required dimensions
Sharpen the splitting wedge, and check
for any burrs or notches
Place a sheet of cardboard under the
log splitter in order to locate the leak.
To correct the problem, refer to the
manufacturer.
Check the oil level and add more oil if
necessary.
If the problem cannot be rectified, refer
to the manufacturer.
Use the correct connecting lead
Log ram travels out je
rkily or under heavy
vibration
Air in the circui
t Open the bleed screw
Check the oil level and add more oil if
necessary.
If the problem cannot be rectified, refer
to the manufacturer.
Log ram will not move out
Hydrau
lic pump defective To correct the problem, refer to the
manufacturer.
Motor will not start
No electrical powe
r
Connection cable defective
Electric motor defective
Check the fuse (13A).
Replace the connection cable or have it
checked by an electrician.
To correct the problem, refer to the
manufacturer.
Oil leak at the dipstick
Oil seal at the dipstick not s
ealin
g Replace the oil seal.
T
T
e
e
c
c
h
h
n
n
i
i
c
c
a
a
l
l
d
d
a
a
t
t
a
a
Name
Model
Splitting force
Log length 520 mm
Log diameter
Stroke
Power supply 230 V ~ 50 Hz
Rev
o
l
u
ti
ons 28
20 r
pm
8
LS520H -LS520D
50kN(5T)
COBRA LS520H
T
Trouble Shooting