F. Programming Options
Default settings in BOLD
OPTION DESCRIPTION
Option Bank 0 - 3 Chirps (Learn Transmitters)
Option Bank One - 4 Chirps (Keyless Options) INDICATOR
1. Lite Touch Adj. ARM raises sensitivity: DISARM lowers sensitivity
2. Full Shock Adj ARM raises sensitivity: DISARM lowers sensitivity
3. Ignition Triggered Lock Doors lock when all doors are closed and ON OFF
Ignition is turned on
4.Delayed Ignition 3 sec delay locking for theatre dimming
ON OFF
Triggered Lock
5. Extended Locks Lock duration is (1)5 sec or (2) 0.6 sec ON OFF
6. Ignition Triggered Unlock Doors Unlock when ignition is turned off ON OFF
7. Double Pulse Unlock Unit provides 2 pulses when unlocked ON OFF
8. Extended Horn Pulse Activates Longer Horn Pulse Output ON OFF
Option Bank Two - 5 Chirps (Keyless & Alarm Options)
1. Passive Starter Kill Engages starter kill after one minute O N OFF
2.Passive Arming Alarm automatically arms 60 sec. O N OFF
after ignition is turned off
3.Passive Locks Doors lock automatically after 60 sec ON OFF
4.Confirmation Chirps (1) Yes (2) No confirmation chirps ON(1) OFF(2)
5. Silent Choice (1) By Pressing LOCK o r UNLOCK twice (manual) ON(1) OFF(2)
6. Horn/Siren (1) Horn (2) Siren ON(1) OFF(2)
7. Noise Control Alarm will (1) sound for five 30-sec. cycles, ON(1) OFF(2)
then ignore trigger or (2) Sound continuously
when triggered if an entrance is left open
8. Horn Output (1) Real Panic (2) Pulsed Output ON (1) OFF (2)
Option Bank Three - 6 Chirps (Car Start Options)
1. Tach Mode (1) Use blind crank timing (2) Use tach input ON(1) OFF(2)
2.Blind Crank Time (1) Avg of last 8 manual starts (2) 1 sec. ON(1) OFF(2)
3.Start Confirmation Chirp (1) chirp (2) No chirp ON(1) OFF(2)
4.Run Time (1) 25 minutes (2) 12 minutes ON(1) OFF(2)
5.Diesel Mode Start crank begins (1) 15 sec. or ON (1)OFF(2)
(2) 2 sec. after ignition turns on
6. Lock After Start Locks doors after start command ON OFF
7. Door Trigger Delay (1) Door trigger ignored 60 sec. after start ON(1) OFF(2)
(2) Door trigger always active
8. External Start Trigger (1) External start trigger requires 1 pulse ON(1) OFF(2)
(2) External start trigger requires a double pulse
Option Bank Four - 7 Chirps (Polarity Select Options)
1. Door Trigger Polarity (1) Positive (2) Negative ON(1) OFF(2)
2.External Start Trigger (1) Positive (2) Negative ON(1) OFF(2)
3.Neutral Safety Input (1) Positive (2) Negative ON(1) OFF(2)
4. Tach Learn Tach Programming (Open Hood, Start with key)
5. Aux 1 See table 1. 2
6. Aux 2 See table 1. 2
4. Option Programming