Internal Memory CC28 
Every transmitter is pre-programmed with the data of the most important gases and their additional 
parameters. In most cases, therefore, the user does not need to change the configuration. The 
following information is stored in the internal memory of the transmitter: 
Gas Formula Unit CGAS
 (test gas) 
 A1
(Alarm 1)
 A2
(Alarm 2)
 H1 
(Hyst. A1) 
 H2 
(Hyst. A2) 
 F1 
(Funct. A1)
 F2 
(Funct. A2)
Methane CH
4
  %LEL   45.5   20.0  40.0  1.0   1.0  NS  SC 
Ethane C
2
H
6
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Propane C
3
H
8
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Butane C
4
H
10
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Pentane C
5
H
12
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Hexane C
6
H
14
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Heptane C
7
H
16
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Octane C
8
H
18
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Nonane C
9
H
20
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Iso-Butane (CH
3
)
3
CH  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Cyclohexane C
6
H
12
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Ethylene (Ethene)  H
2
C=CH
2
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Propylene (Propene)  H
2
C=CH–CH
3
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Acetylene (Ethine) 
HC≡CH 
%LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Propine 
HC≡C–CH
3
%LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Hydrogen H
2
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Benzene C
6
H
6
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Toluene C
6
H
5
-CH
3
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Xylene C
6
H
4
-(CH
3
)
2
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Methanol CH
3
OH  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Ethanol C
2
H
5
OH  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Iso-Propanol (2-Propanol)  CH
3
-CHOH-CH
3
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
2-Butanol CH
3
-CHOH-C
2
H
5
%LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Dimethyl ether  CH
3
-O-CH
3
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Diethyl ether  C
2
H
5
-O-C
2
H
5
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Aceton CH
3
-CO-CH
3
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
2-Butanon (MEK)  CH
3
-CO-C
2
H
5
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Methyl acetate  CH
3
-COO-CH
3
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Ethyl acetate  CH
3
-COO-C
2
H
5
  %LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Methylisobutylketone 
(MIBK) 
CH
3
-CO-
CH(CH
3
)
3
%LEL   50.0   20.0  40.0  1.0   1.0  NS  SC 
Ammonia (0 – 4 Vol.%)  NH
3
  Vol.%   3.0   1.0   3.0   0.1   0.1  NS  SC 
If the transmitter is operated with a sensor for which no data are entered yet in this list, defined 
settings are being used. 
The user can adapt these settings individually and store them in the transmitter. 