Specifications
  Hydronic D4W SC   Hydronic D5W SC   Hydronic D5W S   Hydronic B4W SC   Hydronic B5W SC
     Hydronic B5W S
  8.4 cm3 / 90 seconds   9.5 cm3 / 90 seconds   8.6 cm3 / 90 seconds   11.3 cm3 / 90 seconds   11.9 cm3 / 90 seconds   Max
  7.3 cm3 / 90 seconds   8.5 cm3 / 90 seconds   7.6 cm3 / 90 seconds   10.1 cm3 / 90 seconds   10.7 cm3 / 90 seconds   Min
Hydronic B4W SC 
Hydronic B5W SC
Hydronic 
B5W 
S
11.3 cm3 / 90 seconds 
11.9 cm3 / 90 seconds 
10.1 cm3 / 90 seconds 
10.7 cm3 / 90 seconds 
6
Maintenance / Troubleshooting & Repair
18
REVISION LEVEL A - 12/09/13
FUEL QUANTITY TEST
The  fuel  Quantity  should  be  tested  if  the  heater  has  difculty  starting  or 
maintaining a ame, using graduated cylinder part # 5520004 10ml.
Measure the fuel quantity when the battery is sufciently charged. At least 11V 
and at most 13V should be applied at the control unit during measurement.
PREPARATION
•  Remove metering pump cover in the cases of SC versions.
•  Pull the fuel line off the combustion chamber and insert into a graduated 
  measuring glass.
•  Switch the heater on, when fuel delivery is uniform (approximately 40
  seconds after switching on), the fuel line is full and bled.
•  Switch heater off.
•  Empty measuring glass and replace.
MEASUREMENT
•  Switch heater on.
•  Fuel delivery starts automatically approximately 40 seconds after 
  switching on.
•  Hold the graduated measuring glass at the glow pin height during 
  measurement.
•  After 90 seconds of fuel delivery, it will shut off automatically.
•  Switch heater off.
•  Read off quantity of fuel delivery in the graduated measuring glass.
EVALUATION
If measured quantity of fuel is over or under the nominal value,
the metering pump must be replaced or fuel restriction eliminated.
  Figure 12
DIESEL  GASOLINE
PLEASE NOTE!