Technical data
(!) ATTENTION (!)
Activation of the emergency lever or of the reactivation button of the 
electrovalve.
This activation prevents the operation of the lifting moment limiting devi-
ce, consequently, the operation under such conditions can involve an 
overload condition. In such an emergency condition (where the lifting 
moment limiting device has been disabled), the operator, who is respon-
sible for the machine safety, must:
-  carefully consider the manoeuvres required to return to normal working 
  conditions: it is however compulsory to effect the re-entry of the exten-
  sion booms at first,
-  calmly and carefully assess the type and scale of the hazards arising
  from these manoeuvres and the possible reaction of the crane (tipping
  over, frame overload, uncontrolled fall of the load due to a hydraulic
  system overload etc.);
-  make all movements as slowly as possible to reduce the dynamic 
  overload to the minimum.
After such emergency operations and prior to re-use of the crane, you must 
immediately go to FASSI authorised Center for testing the structure and re-
sealing of the device.
(!)  Interferences with the valves or removal of the lead seal release
  the   FASSI GRU IDRAULICHE
  from any responsibility and invalidate the warranty.
(!) ATTENTION (!)
The presence of the lifting moment limiting device does not release the 
user from the obligation to respect what is indicated on capacity plates 
and lifting curves.
16.9
CONTROLS TO 
OPERATE THE CRANE
GR2_50_65_3_80