Technical data
24
POSSIBLE FAULTS
GRU FASSI 
24 POSSIBLE FAULTS
24.1 Generality
Many years experience of our product has allowed us to identify and classify the most 
common faults which occur. In most cases it requires accurate hydraulic and electric 
troubleshooting and simple rectification. In the following table we report the most fre-
quent inconveniences and our suggested remedies.
(!)  Checking and adjustment of oil pressures of valve settings must be carried out
  by an authorized service agent, under penalty of warranty forfeiture.
 (!) ATTENTION (!)
In the event that the crane ceases to operate and the code "alarm" with a number appears 
on the Display B. Call your FASSI authorised service centre reporting the Alarm number 
with the crane model and serial numbers. If the fault cannot be cleared follow the procedure 
in the chapter "Controls to operate the crane" and overide the dump valve EVI.
THIS IS ONLY A TEMPORARY ACTION FOR EMERGENCIES, the crane should be 
taken to a FASSI service centre for repair as soon as possible.
TO OPERATE THE CRANE FOR TOO LONGER PERIOD WITH THE OVERIDE 
ACTIVATED MAY INVALIDATE THE CRANE WARRANTY.
24.2 
Only operations which can be carried out by the user
Note:  Any operation, other than those indicated hereunder, must be performed
  only and exclusively by specialized personnel from an authorized support 
  centre, considering the potential residual risks. 
 FAULTS  CAUSE  REMEDIES
  The crane does not  Vehicle non  Stabilize the vehicle
  rotate properly  in level position 
    Lack of lubrication  - WITH RACK:
      Grease the bushes and
      the rotation guide shoe
      - WITH SLEW RING:
      Grease the slew ring 
       and the pinion gear-
  slew ring group
  The extension booms  Lack of lubrication  Grease
  do not completely extend  of the guide shoes   the guide shoes
  or work jerkily   
  Crane controls are  Lack of  Check the fuse,
  not active   electric energy  the battery and
  electric circuit
    Winch stroke end  See 21.2
    active (if fitted) 
    The rotation limiting  See 16.6
    device is activated
  Vibrations in  Shortage of oil  Check the level
  crane operations    and top up
      if necessary
    Obstructed filters  Clean or replace 
      the filter cartridge
  Noteable decrease in  Obstructed filters  Clean or replace
  movement speed    the filter cartridge