 FAULTS  CAUSE  REMEDIES
  The crane does not lift  Non efficiency  Replace the pump
  the loads indicated  of the pump
  on the capacity plate
    (main pressure or auxiliary)  Check the pressure,
     valves not properly  adjust the valves
    adjusted, or worn  or replace them!
    Ram seals are  Replace the seals
    not properly fitted
  A boom of the crane  The safety check valve  Replace the valve
  does not hold up the load  the ram is open
  and visually lowers
    Oil leaks inside the ram  Defective seals,
      replace them!
  The crane does not  Valves controlling the  Adjust the valves
  rotate properly  rotation not adjusted
  - WITH RACK:  Wear of rotation guide shoe  Replace the guide shoe
    Wear of the seals  Replace the seals
    of the rotation cylinder
  - WITH SLEW RING:  Wear of the slew ring  Check the slew ring wear,
      replace if necessary
    Wear of the  Check the motore-
    motoreducer group  ducer group wear,
      replace if necessary
  The extension booms  Wear of guide shoes  Check the 
  do not completely extend    guide shoes wear, 
  or work jerkily    replace if necessary
  Vibrations in  Non efficient pump  Check the pump
 crane operations
  Noteable decrease in  Non efficient pump  Check the pump
 movement speed