Operating instructions
http://www.coef.net - info@coef.it Pag. 5
G
A
In case of replacement of the lamp or maintenance, do not open the fixture unless 5 minu
-
tes have passed from the switching off.
This operation has to be done when the apparatus is disconnected from the mains supply.
1) Disconnect power before lamp’ s replacement. Wear gloves and goggles.
2) Remove completely the pommels (A) on the base of the head
3) Open the base of the lamp room (G)
4) Remove the two lateral reflectors (C1) or (C)
5) Lift up the two lampholder (D)
6) Install the new lamp. Taking care that protuberance of the bulb is set towards the reflector
Do not touch the quarz bulb with fingers. If this happenes, clean the bulb before use with dry cloth and alcohol.
7) Put down the two upper lampholders (D)
8) Connect the cables (E) to the two ends of the lamp (MHD1800 or MHD2500) or connect the two cables of the lamp to
the two red insulators on the rear panel of the head.
9) Put in again the two lateral plane reflectors. To obtain a wider optic (beam) use the C1 shaped reflectors. For a nar-
row optic (beam) use the C flat reflectors.
10) Close the rear panel and install again the two pommels (A) and hold them tightly.
INSTALLATION OF THE DISCHARGE LAMP MSD 1200W, MSR 1800W
IP RATE - INSTALLATION OF THE DUST PROOF FILTERS
The declared IP rate of the Sirio 1800DV/2500DV comes supported at these conditions:
• the installation of the fixture on a wide and stable surface
• the air cooling input and output are located on the base of the side-shell,
The Sirio 1800DV/2500DV has a IP rate 44 without filters installed and an IP RATE 54 with filters installed.
You must use the filters in critical working conditions and, normally, when the fixture works outdoor.
You must remove the filters when the ambient temperature is over 35°C.
You must remove the two side protective shells. The two filters must be
assembled on the bulkheads at the bottom of the side brackets.Pay attention to the
installation: dust proof filters must stick correctly to prevent the entrance of the dust.
You must control that the two filters completely cover the overall of the air entrance.
You must operate with power
supply disconnected from the fixture.
fig.3
fig.2
D
C
E
C
C1