Operating instructions
Pag. 2 http://www.coef.it - info@coef.it
This equipment is destined to an exclusively Professional use.
READ ALL CAUTIONS AND WARNINGS PRIOR TO OPERATE THIS EQUIPMENT.Instruction to prevent injury or damage
due to electric shock, fire, mechanical hazards and UV radiation hazards.
•PROTECTION AGAINTS FIRE
1)This equipment is designed for use with the following lamps only: Mastercolour 150W • CDM-T 150W/942 • CDM-SA/T
150W/942. Do not use any other type of lamp!
2) Maintain minimum distance of 0.3 meter from walls or any other type flammable surfaces.
3) Maintain minimum distance of 1.0 meter to lighted objects .
4) Replace fuses only with the specified type and rating.
5) Do not install the spot close to heat sources. Do not lay the connection cable on the spot when it is warm.
•PROTECTION AGAINST ELECTRIC SHOCK
1) This equipment must be earthed.
2) Class I equipment. The power supply cord includes a protective earthing conductor as part of the cord.
3) For connection to the mains supply proceed as pict.3 page 6.
4) Disconnect power before installing the lamp or servicing (service personnel).
•PROTECTION AGAINST MECHANICAL HAZARDS
1) Use secondary safety chain when fixing this equipment.
2) Hot lamp explosion hazard. Do not open the equipment for 300 seconds after switching off.
3) Equipment surface may reach temperature up to 90°C. Allow about five minutes before handling.
4) Replace the lamp if it is damaged or thermally deformed and however after 6000 life hours.
•PROTECTION AGAINST UV RADIATION HAZARDS
1) Do not start on this equipment without lamp enclosure or if the protection screens, or ultraviolets screens are damaged.
2) The protection screens, the lenses, or the ultraviolet filters must be replaced if they are visibly damaged and their effective
-
ness has been reduced, for example, by cracks or deep scratches.
3) Do not look directly at the lamp while lamp is on.t
ATTENTION: carefully read the directions of this manual. Exclusively follow the safety rules in force and do not carry
out assembly and/or maintenance operations without taking all precautions as indicated in the different sections or
without the necessary specialization.
This manual must always accompany the equipment, therefore it must be available and readable at any moment if
necessary. Also in case of sale, rent, change of place and/or ownership, these documents shall be enclosed with the
relative equipment.
INTRODUCTION
Thank you for using the Sirio 150 / 150DV !
The Sirio 150 / 150DV projects, thanks to an extremely efficient optic system (international patent n. WO99/40361), a powerful
light beam which can create numberless color shades. Its performances, in terms of luminousity and lighted surfaces, can reach in
-
credible levels.
The Sirio 150 / 150DV comes in two versions:
• Cod. 02B010 Sirio 150 for Mastercolour 150W (CDM-T 150W/942 - CDM-SA/T 150W/942).
• Cod. 02B011 Sirio 150DV with shutter for Mastercolour 150W (CDM-T 150W/942 - CDM-SA/T 150W/942).
The Sirio 150 / 150DV can work in automatic mode or in synchro mode, otherwise may be controlled by 8 bit DMX controllers.
The input protocol is the DMX 512. To drive the Sirio 150 / 150DV we suggest to use our controller MasterShow 512.
To make the most of its possibilites and for a correct functioning of this unit in the years to come, we suggest you to read
carefully this manual before connecting or putting the spot into use. By doing so you will gain experience with its commands and
connections and you will be easily able to use it.
ADVICES FOR A CORRECT INSTALLATION
Declaration of CE conformity
COEF srl. Via Albinatico, 80-82 / 51019 Ponte Buggianese (Pistoia) ITALY
Declare that the product
Sirio 150 / 150DV is in conformity with 89/336 EEC-EMC directive and
with the actual required safety standars in accordance with LVD 73/23 EEC