Printer User Manual

Copyright © 2006, Cognitive - 1.800.525.2785  61 
105-169-03 
save your setting, then press Calibrate to perform the calibration. The 
printer will respond with a ‘Successful’ or ‘Unsuccessful’ status message. 
Method 2: Calibrate by Performing a Self Test; See Chapter 2 
of this User’s Guide 
When the Self Test has finished printing the printers default settings, the 
text ‘Press Feed Switch Now to Calibrate Index’ will appear on the media. 
Press the Feed switch at this time to perform the calibration. 
Once completed, the Printer must be power cycled to return to its proper 
printing state. 
If calibration was successful, pressing the Feed button will eject only one 
label at a time. 
Method 3: Calibrate Using Cognitive Programming Language (CPL)
Use the Administrator’s CPL Editor tab (see below) to send the following 
commands to the printer. 
! 0 0 0 0 
VARIABLE INDEX ON 
VARIABLE FEED_TYPE GAP 
VARIABLE INDEX SETTING CALIBRATE 
VARIABLE WRITE 
END 
Notice the keyword GAP in the third line. This may be replaced by the 
keywords BAR or Notch as you need. 