VARIABLE ENERGY 
Function  The printer maintains a fixed energy density of 200 
mJoules independent of print speed. This command 
adjusts the energy density (in units of mJoules). It 
is intended to be used to compensate for media that 
requires more or less energy to create images of the 
proper optical density. VARIABLE DARKNESS 
may be used by the customer, but this command is 
intended to be an easier to use, more precise optical 
density control command for the C-series printer. 
Explicit Form 
Implicit Form 
VARIABLE ENERGY energylevel/? 
V energylevel/? 
Parameters 
Comments 
•   
Example 
lLongStackCount 0 (query form) or 1 
lpLongStack[0] energylevel (EnergyRange) 
FUNCID=VARENERGYID=170 
NOBUFFER 
ImpUserEnergy 