Blazer Compatibility
As shipped, Barcode Blaster, Solus, and Blaster Advantage printers are
not compatible with older Barcode Blazers, or with enhanced Blazers
operating in nonlinear dot time mode. High speed Blasters can closely
emulate Barcode Blazers. Solus and Advantage printers are more
limited in their Blazer emulation.
As a rule, only use Blazer emulation mode if you are replacing an older
Barcode Blazer and must avoid modifying any label formats or software.
Do not use Blazer emulation mode if you can print successfully without
it.
Blazer emulation mode is controlled by the VARIABLE MODE command.
VARIABLES ON/OFF controls access to VARIABLE MODE. Please refer to
these command descriptions before using the label formats.
The following label format sets up any Barcode Blaster to emulate an
enhanced Barcode Blazer operating in linear dot time mode:
! 0 0 0 0
VARIABLE MODE 1
VARIABLE WRITE
END
The following label format will set up a high speed Blaster to emulate a
non-enhanced Blazer or an enhanced Blazer operating in nonlinear dot
time mode. Adjust the second parameter in the VARIABLE MODE
command to compensate for the speed of the Blazer that you are
replacing. The value shown (70) will vertically scale all labels to 70% of
their normal height.
! 0 0 0 0
VARIABLE MODE 2 70
VARIABLE WRITE