Numeric values do not increment properly in response to the 
ADJUST command. 
42. Cause: The numeric value you wish to adjust has more digits 
than the parameter specified in the ADJUST command. 
Cure: Pad the ADJUST parameter with leading zeros as required. 
43. Cause: You are trying to adjust a numeric value to a number 
with more digits than the original value. 
Cure:
 Pad the original value with leading zeros as required. 
44. Cause:
 You are using a MULTIPLE command with ADJUST. 
Cure: This is acceptable, but remember: ADJUST will only increment 
the adjusted numeric value when the printer feeds a label. Duplicate 
labels printed side-by-side will always be identical. 
45. Cause: You are trying to increment numeric data that does not 
appear at the end of a command line. 
Cure: This may be acceptable, but the ADJUST command can only 
increment numeric data. If alpha characters follow the numeric 
data, you must follow the ADJUST parameter with enough zeros to 
pad the increment value away from the alpha characters. 
Bar code or string positioning is incorrect. 
Cause: A required space was left out or an extra space was inserted 
somewhere in the BARCODE or STRING command, causing the 
printer to interpret the parameters incorrectly. 
Cure: Use blank spaces as shown in the command descriptions. 
Ultra Font or TEXT font positioning is incorrect. 
Cause: The label format has a JUSTIFY command in it that you have 
not accounted for. 
Cure: Each JUSTIFY command in a format will remain in effect for 
the rest of the format or up to the next JUSTIFY. Insert new 
JUSTIFY commands where required. 