Monitor Descriptions:
Input Power Indicating the input power of both DL and UL detected by the repeater.
Gain Indicating the DL and UL gain of repeater. UL gain will display as N/A during
UL standby mode (blue sleep button).
Output Power Displays the DL and UL output power of the repeater. UL output power will
display as Low during UL standby mode (blue sleep button).
CH1 Displays the DL and UL working status of first 5MHz of your 15MHz
selection. DL will show sleep when channel is switched off or when no signal
of this channel is detected.
CH2 Displays the DL and UL working status of middle 5MHz of your 15MHz
selection. DL will show sleep when channel is switched off or when no signal
of this channel is detected.
CH3 Displays the DL and UL working status of last 5MHz of your 15MHz
selection. DL will show sleep when channel is switched off or when no signal
of this channel is detected.
Isolation Displays the isolation value detected by repeater.
AGA ATT Adjustment made by AGA when isolation is insufficient.
Temperature Operating temperature of the repeater.
Alarm Descriptions:
DL Over Power This can happen when DL input power reaches -32dBm or higher.
UL Over Power This can happen when too many people are using the repeat
simultaneously.
Isolation Triggers when isolation value is <35dB.
Over Temperature Triggers when temperature is over 75°C. Repeater will recover at 65°C.
PLL-Unlock Triggered when repeater hardware fails. If alarm persist, contact Coiler for
warranty information.