B. Operator Screenshot
The ICS function generates interference signal to the testing equipment and would distort the testing
result. Hence a list of different test modes can be found under “admin” and “operator” account. Please
select the appropriate test mode according to the testing parameters to ensure accurate result.
Test Mode Purpose
ICS ON
Default setting. Always select this option to ensure proper functioning of PS.
ICS UL Select this option to test UL standby mode.
DL ICS OFF UL PA would be off and DL signal would become analog with this test mode.
UL ICS OFF DL PA would be off and UL signal would become analog with this test mode.
OUT BAND GAIN Select this test mode to test out of band gain.
NOISE FIGURE Select this test mode to test noise figure.
Both “admin” and “operator” also has the ability to switch AGC Trailing on/off. When AGC trailing is on,
UL AGC will follow DL AGC. By default, AGC trailing is off so UL and DL AGC would work
independently.