9. Troubleshooting
Please first refer to troubleshooting section of the Quick Installation Guide.
Situation
Solution
There is still no signal after the
installation
of the
equipment.
Ensure that the output power of the Adaptor is DC 6V /
6A and that green power LED is illuminated.
Ensure that all connections are tightly fastened.
Ensure that the outdoor signal level (RSSI) is sufficient.
(Coiler recommends a signal strength greater than -
80dBm, or three green RSSI LED).
If external donor antenna is used, ensure that all
connections are tightly fastened.
Reconnect the power cable.
The signal strength is too weak
in
the corner.
Ensure a strong donor signal level (RSSI) of -80dBm or
better is achieved (three green RSSI LED).
Adjust the placement location of the PS repeater or
consider using external donor antenna.
Use the coupler port to install additional service
The repeater’s signal is not stable.
Ensure that the outdoor signal is stable.
If external donor/service antenna is used, ensure that
the Isolation LED has five green LED.
Consider changing location of PS repeater or connect
The red Alarm LED is lit.
Ensure that input RSSI is not -32dBm or higher.
If alarm persist even though RSSI is less than -32dBm,
Log into OMT to review the alarms list for exact alarm
description.
For PLL-Unlock alarm, contact a Coiler representative.