15
5.6. Connecting the Cables
The RF connector type of the repeater and the cable is SMA. Please
ensure that the pin head of the connector is all right before plugging it in.
1. After mounting the donor antenna, plug the antenna connector into
the RF cable and ensure that they are tightly fastened.
2. Route the RF cable into the house and ensure that the cable is
fastened all the way into the house.
3. Plug in the donor antenna cable (marked as ‘BTS’), extended
service antenna cable (marked as ‘MS CPL’. If the extra indoor
antenna is used) and the DC power adaptor (DC side, marked as
‘DC 6V’) into the repeater. But DO NOT plug the AC side power
connector into the AC power source at this moment.
Donor
Antenna
(female)
RF Cable
(male)
DC Power Port
(DC 6V)
Optional
Extended Service Antenna
Port. (MS CPL)
Donor Antenna
Port. (BTS)