8 7 6 5 4 CROSSFLOW INSTALL MANUAL D 2 3 1 CONTENT PAGE PLENUM INTRO PLENUM WALLS ASSEMBLY PLENUM FILTER INSTALL WALL INSTALL WALL AND ROOF INSTALL FRONT FACE INSTALL DOOR INSTALL ELECTRICAL INSTALL 2 3 4 5 6 7 8 9 D C C REFER TO THE INCLUDED PACKING LIST FOR MORE INFORMATION ON PARTS AND PART NUMBERS. B B COL-MET SPRAY BOOTHS 1635 INNOVATION DR. ROCKWALL, TX 75032 PHONE (972) 772-1919 FAX (972) 772-1833 WWW.COLMETSB.
8 7 6 5 4 3 2 1 PLENUM INSTALL INSTRUCTIONS D D C C B B COL-MET SPRAY BOOTHS 1635 INNOVATION DR. ROCKWALL, TX 75032 PHONE (972) 772-1919 FAX (972) 772-1833 WWW.COLMETSB.
8 6 7 5 4 PLENUM INSTALL INSTRUCTIONS 1. 2. D 3. 5 4 4. 5. 6. 10 2 3 1 ANCHOR TIE CHANNEL 10 TO THE FLOOR ATTACH PANEL 1 TO CHANNEL 10 WITH SUPPLIED 5/16"Ø NUTS AND BOLTS ATTACH PANELS 2 TO PANEL 1 ON BOTH SIDES ATTACH PANEL 2 ATTACH PANEL 5 TO PANEL 2 AND PANEL 1 ATTACH FAN PANEL 4 TO TIE CHANNEL 10 AND PANEL 5 D 1 C C 2 10 B B 1 COL-MET SPRAY BOOTHS 1635 INNOVATION DR. ROCKWALL, TX 75032 PHONE (972) 772-1919 FAX (972) 772-1833 WWW.COLMETSB.
8 6 7 5 4 2 3 1 PLENUM INSTALL INSTRUCTIONS D D 1. 2. 3. 6 4. PLACE FLOOR CHANNEL 8 ON GROUND ATTACH PANEL 7 TO PANEL 1 ON BOTH SIDES ATTACH PANEL 6 TO FAN PANEL AND PANELS 7 ATTACH FILTER RACKS 9 TO PANELS 7 AND 6 C C 7 9 7 B B 8 A COL-MET SPRAY BOOTHS 1635 INNOVATION DR. ROCKWALL, TX 75032 PHONE (972) 772-1919 FAX (972) 772-1833 WWW.COLMETSB.
8 6 7 5 4 2 3 1 WALL AND ROOF INSTALL INSTRUCTIONS D D 16 1. 2. ATTACH PANELS 11 TO PLENUM ATTACH PANEL 12 TO PANEL 11 AND PLENUM 3. ANCHOR TIE CHANNEL 21 AND26 TO FLOOR 4. ATTACH PANEL 16 ON LEFT SIDE 5. ATTACH ACCESS DOOR 19 TO RIGHT SIDE 6. ATTACH PANEL 18 TO ACCESS DOOR 7. ATTACH TIE CHANNEL 25 TO BOTH SIDES 8. ATTACH PANEL 20 TO ACCESS DOOR 9. ATTACH PANEL 16 ON RIGHT SIDE 10. ATTACH PANEL 17 TO LEFT SIDE 11. REPEAT STEPS 9 & 10 12.
8 7 6 5 4 3 2 1 WALL AND ROOF INSTALL INSTRUCTIONS D D REPEAT STEPS 3 & 4 UNTIL YOU HAVE WHAT IS SHOWN HERE C C B B A D D I T I O N A L D U C T WO R K S U P P O R T T O S U I T F I E L D C ONDI T I ONS T OB E S UP P L I E DB Y OT HE RS . A L L A NC HORB OL T S T OB E S UP P L I E DB Y OT HE RS . COL-MET SPRAY BOOTHS 1635 INNOVATION DR. ROCKWALL, TX 75032 PHONE (972) 772-1919 FAX (972) 772-1833 WWW.COLMETSB.
8 6 7 5 4 3 2 1 WALL AND ROOF INSTALL INSTRUCTIONS D D C C 15 14 B 1. 2. 3. 4. ATTACH PANELS 13 TO BOOTH WALLS ON BOTH SIDES ATTACH PANEL 14 TO BOOTH ROOF ATTACH DOOR STOP 15A TO PANEL 14 ATTACH DOOR 15 (SEE STEPS ON NEXT PAGE) B 15A COL-MET SPRAY BOOTHS 1635 INNOVATION DR. ROCKWALL, TX 75032 PHONE (972) 772-1919 FAX (972) 772-1833 WWW.COLMETSB.
7 6 5 4 3 2 1 DOOR INSTALL INSTRUCTIONS D D C C B B 1. A 2. ATTACH LEFT DOOR SIDE BY BOLTING 10 GAUGE DOOR CHANNEL TO PLENUM PANELS REPEAT FOR OPPOSITE SIDE COL-MET SPRAY BOOTHS 1635 INNOVATION DR. ROCKWALL, TX 75032 PHONE (972) 772-1919 FAX (972) 772-1833 WWW.COLMETSB.
8 7 6 5 4 3 2 1 INSTALL ELECTRICS HAVE A CERTIFIED ELECTRICIAN INSTALL THE LIGHTS, FAN, MANOMETER AND AIR SOLENOID VALVE. D D C C B B COL-MET SPRAY BOOTHS 1635 INNOVATION DR. ROCKWALL, TX 75032 PHONE (972) 772-1919 FAX (972) 772-1833 WWW.COLMETSB.