Operation Manual

53 BEAUTY ** - BEAUTY LUX **
- At first startup, remove all the components (instructions/label) that could burn from the stove firebox
and glass.
- Any lightings done after long stove idle periods require the renewal of any pellets that have been inside
the hopper for a long time, in being a damp fuel no longer suitable for combustion, and complete
cleaning of the combustion chamber.
4.3.2 Startup stage
To light the stove, press the button ‘P4’ for 3 seconds: the message ‘START’ will appear on the display.
The stage is automatic and managed entirely by the electronic controller without the possibility of changing the
parameters.
The stove carries out the startup stages in sequence according to the procedures defined by the parameters that
manage levels and times, reaching the work condition unless anomalies or alarms occur, according to the following
table:
After a certain time has elapsed, if the fume temperature has not reached the minimum permissible value the stove
goes in alarm status.
- Do not use flammable liquids to light the stove.
- In case of persistent failed lighting, contact the Service Centre.
Clock
Dialogue box Output
Room temperature
Button ‘P4’
Status
Duration
Devices
Conditions for going to next status
Igniter
Fume
exhaust
Auger
Exch.
OFF
START – CLEANING
PELLET PREFILL
WAITING FLAME
PELLET LOAD
FIRE PRESENT
WORK
MODULATES WORK
BRAZIER CLEANING
WORK
FINAL CLEANING
ON/OFF to switch off
(*) Pr39 starts from when fume T.< Pr13
Room temperature < SET temperature
Fume temperature < Pr14
Room temperature < SET temperature
Fume temperature < Pr14
Every Pr03
After time Pr33
After timePr34
After time Pr40
After timePr41
Fume temperature > Pr13
After time Pr02
PREHEAT