Operation Manual

T-POWER30_T-POWER 30S
50
The request for these accessories must go with the supplementary electronic board model ‘I055’ for management of
commands with possible upgrading of software to be placed on the control main board.
After completing the DHW connection it is necessary to access the technical menu of the control and select the type
of circuit; every specific DHW function set: DHW EXCHANGER, BOILER or DHW BOILER appears on the display at
the moment of heating-DHW switchover with one of the messages given below and remains until the end of the
DHW request by the thermostat or flow switch :
Hydraulic diagram - heating pellet stove with sanitary pump
Heating pellet stove
Thermostat
T
>
85°C
Pellet heating
chamber - 2011
Pt=20-25 kW
Heating DELIVERY
male 1“
Water supply F1/2”
Pmax 2 bar
KEY
Arrangement
PLUMBING CONNECTIONS on back of
stove
Heating RETURN
male 1“
Heating DELIVERY
male 3/4“
Heating RETURN
male 3/4“
OVERPRESSURE WATER
DISCHARGE F1/2”
Int. volume 23.5 l
t
.
Drain cock
Pressure sensor / Pressure gauge
Non-return valve
Circulating pump
Membrane pressure vessel
Shutoff valve / Cock
Circuit / heating chamber air ven
Valves to be included in system
during installation – not supplied
with the unit
Safety valve P max 3 bar
Safety sensor T > 85°C
Water temperature sensor
Circuit pressure sensor