Owner`s manual

Common Hardware Problems (continued)
Problem Usual Cause Solution
Noisy pump Clogged floor suction or skimmer. Clean floor suction/skimmer.
and motor.
Low water level. Add water to normal water level (6"
below lip).
Damaged or worn motor bearings. Contact dealer.
Water Check unions & drain hoses. Close or tighten as necessary.
leakage from
under spa.
No air flow Air control not open. Open control.
from jets.
Jet nozzle not seated properly. Check jet nozzles.
Jet nozzle missing. Inspect jets and replace as needed.
Motor will House circuit breaker tripped or in Reset circuit breaker
not operate. OFF position.
Improper or defective wiring or Contact dealer.
electrical supply.
Thermal Overload Protection switch Auto reset after motor has cooled.
tripped. Contact dealer if motor continues to
cycle.
Black powder Wearing in of turbo/blower brushes. Will disappear after use.
film around
water line.
The spa will Spa trying to heat Check “Set Temperature” in Standard
not shut off mode
Spa is in filter cycle Normal. No need to change.
Spa is in standard Mode. Check mode setting.
29