Product Manual

CAUTION: D O NOT OVERSCREW THE M16 NUT THIS WILL PREVENT THE
TURBINE FROM SPINNING FREELY
Place the nose cone over the center line of the blades assembly and snap the nose
cone into
place.
Run all wires close to the batteries. Connect the Stop Switch referring to the diagram in
your manual.
CAUTION: DO NOT CONNECT TO THE B ATTERIES AT THIS POINT!
ENSURE YOUR TURBINE IS CORRECTLY GROUNDED.
Carefully raise the tower and secure base and/or guy cables.
Make sure the Stop Switch is in the off position, then connect wires to the batteries (Red
wire to Positive, Black wire to Negative).
Turn on the Stop Switch, you will see the red LED slowly blink four times to indicate that the
controller is running properly.
CONGRATULATIONS! YOU HAVE COMPLETED YOUR WIND TURBINE INSTALLATION
MAINTENANCE:
Your Coleman Wind Turbine has been designed to run for long periods without requiring
any maintenance. Performance will be enhanced if you periodically inspect your system.
Review the following simple maintenance procedures and implement every six months.
Caution: Do not go near the wind turbine during operation.
• Check blades for superficial damage. Replace blades if damaged. It is important to not
use blades that are damaged, as you will lose overall balance, resulting in a decrease in
efficiency. Should you notice damage to the blades you must replace all 3. The blades are
balanced as sets.
• Check the blade bolts and the hub nut for tightness.
• Check nosecone for cracks and tighten nuts.