Specifications

Genesis Spa
LTR50001108, Rev. B
Operating Your Spa
www.c a l s pa s . c o m
13
Your new spa comes equipped with an electric heater. Following the directions listed below will ensure the
most efcient operation:
NOTE: This method is only for spa usage under two hours a week.
Keep the spa’s operating temperature 5˚F below the desired usage temperature when not in use. One
or two hours before use, set the temperature to the desired temperature.
If the spa usage exceeds two hours a week, the set temperature should remain at the desired usage
temperature.
Allowing the water temperature to lower more than 10˚F below the desired usage temperature and reheating
it prior to usage will cause the heater to operate longer than it normally would maintaining the desired tem-
perature. Doing this will increase your operating cost and makes your heater work more than necessary.
Automatic Time outs
These features will automatically turn themselves
off during periods of continuous use:
Low speed pump After 2 hours
High speed pumps After 15 minutes
Spa light After 4 hours
Setting Filtration Cycles
Your spa is programmed to lter twice a day. The
rst cycle will begin 6 minutes after the spa is turned
on and the second cycle 12 hours later. The factory
has programmed the cycle to last for 2 hours but
this can be switched to 4, 6, or 8 hours depending
on your requirements. The default lter time is two
hours.
To set ltration time, turn off the power to the spa
at the time of day you would like one of the ltration
cycles to begin, then turn back on after 30 seconds.
When power has been restored, press either the Up
or Down button then the Jets button. Press ei-
ther the Up or Down button again to change the
ltering cycle duration. When desired duration is
selected press the Jets button to exit.
The low speed pump will run for the duration of the
ltering cycle and if an ozone system is installed it
will be activated.