Product Manual

Collomix Rühr- und Mischgeräte GmbH Force-action mixer
D-85080 Gaimersheim Collomatic XM
Ref.no.: 39.017 Rev. 01-06 Page 13
11. Using for the first Time
Take hold of the handle and the latch bar. Pull them towards you. This opens
the lock.
Pull the swivel arm upwards.
The machine now stands open in front of you. In the mixing tub you will find two
open-ended wrenches and one other tool. Take these out and check that the tub is
empty.
To close the machine, actuate the latch bar again as described above.
Press the swivel arm down.
Release the latch bar while doing so. It will lock into place on its own.
11.1 Opening and closing the machine
11.2 Switching on
The machine must be open.
The mixing tub must be filled and positioned in the machine with the help of the
trolley. The tub must sit correctly in the tub mount.
Switch the power switch to "1".
Unlock the swivel arm and press it down until it locks.
For the 3-phase version: Observe the direction of rotation indicated by the arrow.
If the machine is disconnected from the mains power supply while closed, it has to be fully
opened and then closed again. Then the machine will run again.
Switching on the power
switch
11.3 Stopping
When the set time cycle has been completed the machine switches off automatically.
The
power switch remains at “1”. If you close the machine again the set time cycle will start
running again from the beginning.
If “Continuous mode” is set the machine will stop when it is opened, or it has to be
switched off manually. To do so, switch the power switch from “1” to “0”.
If you open the swivel arm while mixing is in progress the machine will stop
immediately. The power switch remains at “1”. The machine will start up again when
you close the swivel arm. If a time cycle has been set it will start running again at the
beginning.
After opening you should then remove the mixing tub with the help of the trolley.
NOTE:
Please follow the manufacturer’s processing instructions.
Never start the machine if there is any hardened material in the mixing tub or if any of the
mixing tools are jammed.
Always make sure the machine is at a total standstill before you ever take any material
samples.