Service manual

10
in.xe
The following material is
recommended:
4- # 10 screws of appropriate
length with round, truss or
pan head.
4- washers 1/2 OD x 1/16"
thickness.
Select the most appropriate
location on the fl oor for spa
pack and fi rmly attach guide
plate to wooden base with (2)
screws backed by (2) washers.
Slide back side of the unit's feet
into the guide plate. It should
easily slide into place.
Now fi rmly attach unit to
wooden base by using the
remaining (2) screws backed
by (2) washers to fi x the front of
the foot.
Note: The spa pack must be
installed at least 4 inches above
potential fl ood level. If fl oor is
on ground level, pack should
be raised at least 4 inches.
Floor installation procedure
4"
Important!
Please note that countersunk
screws should not
be used as
they can damage the power
box support.
in.xe installation